SDG160000 SDG250000 SDG300000 SDG400000 SDG500000 SDG600000 SDG800000
NEWLAND/OEM
| Availability: | |
|---|---|
| Quantity: | |
100-800kW generator Designed for heavy-duty commercial and industrial applications, these generators deliver reliable prime power or emergency backup for large-scale operations.
Cummins/Baudouin/Weichai/Ricardo engines
Stanford/Leroy-Somer alternator
Capable of multi-unit parallel operation or parallel operation with the grid
Built-in or external ATS.
Optional PMG excitation for superior inductive load capability.
Model | SDG 160000 | SDG 250000 | SDG 300000 | SDG 400000 | SDG 500000 | SDG 600000 | SDG 800000 |
Prime Power(kW) | 128 | 146 | 200 | 260 | 300 | 350 | 540 |
Standby Power(kW) | 140 | 160 | 220 | 286 | 330 | 385 | 580 |
Engine Model | Cummins/Baudouin/Weichai/Ricardo engines | ||||||
Cylinder No. | 6 | ||||||
Displacement(L) | 7.98 | 7.98 | 9.73 | 11.6 | 12.54 | 12.54 | 19.6 |
Dimension | |||||||
Length (mm) | 3350 | 3350 | 3900 | 3350 | 3350 | 4410 | 5000 |
Width (mm) | 1150 | 1150 | 1400 | 1150 | 1150 | 1730 | 1900 |
Height (mm) | 1850 | 1850 | 2000 | 1850 | 1850 | 2230 | 2230 |
Purpose: Backup power during grid failures, not for continuous operation.
Key Applications:
Healthcare: Ensures uninterrupted power for ICU, surgical equipment, and life-support systems during outages.
Data Security: Supports server uptime during UPS transitions in data centers.
Industrial Safety: Powers emergency lighting and fire suppression systems in factories.
Operational Limits:
Max 200 hours/year at ≤80% load to prevent engine wear.
Avoid prolonged use—exceeding limits shortens lifespan.
Purpose: Primary power source with restricted annual runtime (≤500 hours).
Ideal For:
Remote Operations: Mines, islands, or off-grid sites with scheduled maintenance.
Seasonal Needs: Agricultural irrigation or aquaculture during peak demand.
Temporary Sites: Construction projects with unstable grid access.
Critical Guidelines:
Maintain ≤80% load capacity with annual usage caps.
Regular water-cooling system checks (prevents corrosion/clogging).
No overload capability—strict adherence to ratings extends durability.
1. Can generators operate in extreme temperatures?
Answer: Yes, with optional pre-heating (for cold climates) or enhanced cooling (tropical regions). Controllers tolerate -25°C to +70°C.
2. How does water cooling extend generator lifespan compared to air cooling?
Answer: Water-cooled systems maintain stable temperatures under heavy loads, critical for prolonged use (e.g., 2,000–3,000 hours vs. 200–500 hours for gas generators).
3. What safety tests are conducted on the generators?
Answer: High-voltage tests include 1,800V (single-phase) and 2,160V (three-phase), ensuring insulation reliability.
4. What engine brands do you use, and how do they perform?
Answer: Options include Cummins (high-altitude efficiency), Isuzu (low noise/fuel consumption), and Weichai (CRDI technology for precise injection).
5. How do PMG (Permanent Magnet Generators) improve performance?
Answer: PMG systems triple short-circuit current capacity (10-second sustain) and boost motor-starting capability from 33% to 67%.